Customization: | Available |
---|---|
Nature of Source Flow: | Passive inverter |
Certification: | CCC, CE |
Still deciding? Get samples of US$ 209/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Overview
The design of PDM low-voltage/medium-voltage AC-DC bidirectional power supply module adopts advanced soft-switching control technology and current equalization technology, which can realize the bidirectional conversion of AC/DC energy of single-phase AC system and three-phase AC system, and in addition to meeting the zero line current demand of three-phase balanced configuration system.
It also makes the power matching more flexible, so that even if the system is unbalanced due to the matching, the zero line current won't be more than the current of the stand-alone module.
This series of modules has low harmonics, low power consumption, and high efficiency. This series of modules is characterized by low harmonic, high efficiency, high power density, fast charging/discharging conversion, high reliability, and flexible matching.
SUITABLE FOR THE SCENE
1.Single-cell battery formation/dividing equipment
2.Battery module aging/testing equipment
3.Power Supply Aging
4.Welding machine power aging
5.Bi-directional testing of power supply equipment
FUNCTIONAL FEATURES
1.Adaptable to three-phase AC systems or single-phase systems
2.High power factor >0.99, low THDi < 2.5%.
3.Bi-directional soft-switching operation, charging up to 95%, discharging 93.5%.
4.Fast switching between charging and discharging
5.High grid adaptability
6.Long-term operation at 40°C with full load or short-time overload operation
7.Modular design, can be wired / wireless parallel connection
8.Wireless parallel connection to expand power (no limitation on the number of units).
9.Product design conforms to CCC, CE and other standards
Technical Specifications | ||||||||
Model | PDM- 14V3K2W-S |
PDM- 48V3K3W-S |
PDM- 80V3K3W-S |
PDM- 130V3K3W-S |
PDM- 190V3K3W-S |
PDM- 375V3K3W-S |
||
AC Input/Output |
Max Output Power | 3280W | 3360W | 3360W | 3360W | 3360W | 3360W | |
Rated Output Power | 3200W | 3300W | 3300W | 3300W | 3300W | 3300W | ||
Input Format | 1Ph+N+PE/3Ph+N+PE | |||||||
Single Phase Rated Voltage | 220Vac/230Vac | |||||||
Voltage Range | 185 ~ 252Vac | |||||||
Frequency Range | 50/60±5Hz frequency adaptation | |||||||
Current | ≤ 20A | |||||||
AC Current Harmonics | < 2.5%@220V,Full-loaded,< 4%@220V,60% loaded | |||||||
Power Factor | 0.99@220Vac,full-loaded | |||||||
Charge Mode |
AC Output | Rated Voltage | 14Vdc | 48Vdc | 80Vdc | 130Vdc | 190Vdc | 375Vdc |
Rated Current | 228A | 68.7A | 40A | 25A | 17.2A | 8.9A | ||
Voltage Stabilization Accuracy | 1% | |||||||
Ripple Voltage | 1% | |||||||
Efficiency Max | 92.7% | 94.0% | 94.5% | 94.5% | 95.0% | 95.0% | ||
Discharge Mode |
AC Input | Rated Input Power | 2700W | 2700W | 2700W | 2700W | 2700W | 2700W |
Rated Voltage | 15Vdc | 51.5Vdc | 86Vdc | 135Vdc | 206Vdc | 388Vdc | ||
Current | 180A | 52.4A | 31.4A | 20A | 13.1A | 7A | ||
Efficiency Max | 91.5% | 92.5% | 93.0% | 93.0% | 93.5% | 93.5% | ||
General Data |
System | Electrical Isolation | High Frequency Isolation | |||||
Cooling Method |
Forced air cooling, intelligent speed adjustment | |||||||
Wind Direction | By default, the air is in the front and the air is out in the back | |||||||
Parallel Connection |
Direct paralleling without equalizing flow lines, no limit on the number of units | |||||||
Series Connection Max | 2 units are recommended for optimal | |||||||
Environment |
Working Temperature | -20ºC~ 40ºC Full-loaded,Derating above 40ºC | ||||||
Storage Temperature | -40ºC~ 70ºC | |||||||
Humidity | 5 ~ 95% No condensation | |||||||
Working Altitude | < 1000m Full-loaded;1000m ~ 3000m,For every 100m of elevation, the power is derated by 1% | |||||||
Interface | Indicator Status | Operation: green, fault: red | ||||||
Communication | CAN | |||||||
Mechanical structure | Dimension(W × H × D) | 142mm×47mm×335mm | ||||||
Weight(kg) | 2.98(kg) |
Technical Specifications | ||||||||
Model | PDM- 14V2K3W-S |
PDM- 14V2K8W-S |
PDM- 13V3K1W-S |
PDM- 40V3K3W-S |
PDM- 60V3K3W-S |
PDM- 219V3K3W-S |
||
Max Output Power | 2550W | 3200W | 3150W | 3360W | 3360W | 3360W | ||
AC Input/Output |
Rated Output Power | 2300W | 2800W | 3000W | 3200W | 3300W | 3300W | |
Input Format | 1Ph+N+PE/3Ph+N+PE | |||||||
Single Phase Rated Voltage | 220Vac/230Vac | |||||||
Voltage Range | 185 ~ 252Vac | |||||||
Frequency Range | 50/60±5Hz frequency adaptation | |||||||
Current | ≤ 16A | ≤ 18A | ≤ 20A | |||||
AC Current Harmonics | < 3.2%@220V Full-loaded,< 5%@220V 60% loaded | < 2.5%@220V,Full-loaded,< 4%@220V,60% loaded | ||||||
Power Factor | 0.99@220Vac,Full-loaded | |||||||
Charge Mode |
AC Output | Rated Voltage | 14Vdc | 14Vdc | 13Vdc | 40Vdc | 60Vdc | 219Vdc |
Rated Current | 160A | 200A | 230A | 80A | 55A | 15.1A | ||
Voltage Stabilization Accuracy | 1% | |||||||
Ripple Voltage | 1% | |||||||
Efficiency Max | 92.2% | 92.5% | 92.3% | 94.5% | 94.5% | 95.0% | ||
Discharge Mode |
AC Input |
Rated Input Power | 2100W | 2400W | 2100W | 2700W | 2700W | 2700W |
Rated Voltage | 15Vdc | 15Vdc | 14Vdc | 43Vdc | 64Vdc | 228Vdc | ||
Current Max | 140A | 160A | 150A | 62.8A | 42.2A | 11.8A | ||
Efficiency Max | 91.0% | 91.8% | 91.1% | 92.0% | 92.8% | 93.2% | ||
General Data |
System |
Electrical Isolation | High Frequency Isolation | |||||
Cooling Method |
Forced air cooling, intelligent speed adjustment | |||||||
Wind Direction | By default, the air is in the front and the air is out in the back | |||||||
Parallel Connection |
Direct paralleling without equalizing flow lines, no limit on the number of units | |||||||
Series Connection Max | 2 units are recommended for optimal | |||||||
Environment |
Working Temperature |
-20ºC~ 40ºC Full-loaded,Derating above 40ºC | ||||||
Storage Temperature | -40ºC~ 70ºC | |||||||
Humidity | 5 ~ 95% No condensation | |||||||
Working Altitude | < 1000m Full-loaded;1000m ~ 3000m,For every 100m of elevation, the power is derated by 1% | |||||||
Interface | Indicator Status | Operation: green, fault: red | ||||||
Communication | CAN | |||||||
Mechanical structure | Dimension(W × H × D) | 142mm×47mm×335mm | ||||||
Weight(kg) | 2.98(kg) |
Technical Specifications | ||||||||
Model | PDM- 190V10KW-S |
PDM- 150V10KW-S |
PDM- 375V10KW-S |
PDM- 14V4K5W-S |
PDM- 20V4K5W-S |
PDM- 190V4K5W-S |
||
AC Input/Output |
Max Output Power | 10000W | 10000W | 10000W | 4500W | 4500W | 4500W | |
Rated Output Power | 10000W | 10000W | 10000W | 4300W | 4500W | 4500W | ||
Input Format | 3Ph+PE | 1Ph+N+PE/3Ph+N+PE | ||||||
Single Phase Rated Voltage | 380Vac | 220Vac/230Vac | ||||||
Voltage Range | 325 ~ 440Vac | 185 ~ 252Vac | ||||||
Frequency Range | 50/60±5Hz frequency adaptation | |||||||
Current | ≤ 20A *3ph | ≤ 23A | ||||||
AC Current Harmonics | < 5%@380Vac,Full-loaded | < 2.5%@220V,Full-loaded,< 4%@220V,60% loaded | ||||||
Power Factor | 0.99@380Vac,Full-loaded | 0.99@220Vac,Full-loaded | ||||||
Charge Mode |
AC Output | Rated Voltage | 190Vdc | 150Vdc | 375Vdc | 14Vdc | 20Vdc | 190Vdc |
Rated Current | 52.5A | 66.7A | 26.7A | 307A | 225A | 23.6A | ||
Voltage Stabilization Accuracy | 1% | |||||||
Ripple Voltage | 1% | |||||||
Efficiency Max | 95.0% | 95.0% | 95.5% | 93.0% | 93.5% | 94.5% | ||
Discharge Mode |
AC Input |
Rated Input Power | 8000W | 8000W | 8000W | 3500W | 3600W | 3600W |
Rated Voltage | 208Vdc | 160Vdc | 390Vdc | 15Vdc | 21.5Vdc | 208Vdc | ||
Current Max | 38.5A | 50A | 20.5A | 233A | 167.5A | 17.3A | ||
Efficiency Max | 94.0% | 94.0% | 94.2% | 92.0% | 92.8% | 93.0% | ||
General Data | System | Electrical Isolation | High Frequency Isolation | |||||
Cooling Method |
Forced air cooling, intelligent speed adjustment | |||||||
Wind Direction | By default, the air is in the front and the air is out in the back | |||||||
Parallel Connection |
Direct paralleling without equalizing flow lines, no limit on the number of units CAN parallel 8 units |
|||||||
Series Connection Max | 2 units are recommended for optimal | |||||||
Environment | Working Temperature | -20ºC~ 40ºC Full-loaded,Derating above 40ºC | ||||||
Storage Temperature | -40ºC~ 70ºC | |||||||
Humidity | 5 ~ 95% No condensation | |||||||
Working Altitude | < 1000m Full-loaded;1000m ~ 3000m,For every 100m of elevation, the power is derated by 1% | |||||||
Interface | Indicator Status | Operation: green, fault: red | ||||||
Communication | CAN | |||||||
Mechanical structure | Dimension(W*H*D) | 235mm×65mm×388mm | 170mm*44mm*335mm | |||||
Weight(kg) | 6 (kg) | 4 (kg) |
1. The "Maximum Output Capacity" only represents instantaneous capacity and is not intended for long-term continuous operation.
2. Can be custom-made to provide an EPO function, allowing external control for operation/shutdown, and it can also save standby power consumption.
3. A single module is suitable for single-phase AC, and multiple modules in parallel can adapt to three-phase four-wire systems. When the power supply is balanced, the effective value of the N-line current is less than 10% or a maximum of 5A.
4. Modules can work in series or parallel. For series operation, it is recommended not to exceed 2 units, and there is no limit to parallel operation. However, the length of the lines from the power source to the load must be as consistent as possible or use busbars; otherwise, it will affect the current equalization effect. CAN allows parallel operation and provides monitoring and communication functions.
5. When the operating ambient temperature exceeds 40°C, a 10% derating is applied from 40 to 45°C. Shutdown occurs when the internal temperature test point exceeds 80°C.
6. The default airflow direction for the module is front-to-back. For modules with a DC voltage greater than 48V, it can be adjusted to back-to-front as needed.
7. Some products are non-standardized and may be upgraded or adapted based on customer needs or system changes. Therefore, the product specifications are for reference only, and actual communication will prevail.
8. For any requirements not mentioned above, please call to obtain relevant information or specifications.
1. What are the advantages of your company?
We have a robust R&D team, independently develop and produce key components, follow standardized production processes, and control
product quality from the source.
2. Do you accept OEM and ODM? If yes, is there a minimum order requirement?
Yes, we do. We have a professional and experienced R&D team. Minimum order quantities are required.
3. What are the key steps in the quality inspection before product shipment?
Include equipment input/output checks, overall functional tests, 48-hour aging tests, and QC inspections.
4. Do you support sample orders?
Yes, we support sample orders.
5. Where can I obtain pricing information?
We typically provide a quote within 24 hours of receiving your inquiry. If you need urgent pricing, please call us or mention it in your email for expedited assistance.
6. What is the warranty period for your products?
The standard warranty period is usually 1 year.
Nanjing Panda Electronics Company Limited has a long histroy of more than 30 years and strong economic strength. As aprofessional supplier of power products, we have an excellent research and development, production and marketing team, dedicated to product design and development, quality control and inspection, and company operation. In order to provide customers with satisfactory products and services, we have established a modern quality management system. At the same time, we also undertake OEM and ODM orders.